圖片可能僅供參考。
有關產品詳細信息,請參閱規格。
W58-XB1A4A-2

W58-XB1A4A-2

Product Overview

The W58-XB1A4A-2 belongs to the category of thermal circuit breakers and is commonly used for protecting electrical circuits from overcurrent conditions. Its characteristics include a compact design, reliable performance, and easy installation. The package typically includes the circuit breaker unit along with necessary mounting hardware. The essence of the W58-XB1A4A-2 lies in its ability to provide effective overcurrent protection in various electrical applications. It is usually available in standard packaging with a specific quantity per package.

Specifications

  • Voltage Rating: 250VAC, 50VDC
  • Current Rating: 5A
  • Trip Time: 1 hour maximum at 200% of rated current
  • Operating Temperature: -40°C to 85°C
  • Reset Method: Manual reset

Detailed Pin Configuration

The W58-XB1A4A-2 features a standard pin configuration with clearly labeled terminals for easy connection to the circuit.

| Pin Number | Description | |------------|-------------| | 1 | Line Input | | 2 | Load Output | | 3 | Ground |

Functional Features

  • Overcurrent Protection: The W58-XB1A4A-2 is designed to trip and interrupt the circuit when an overcurrent condition is detected, effectively preventing damage to the connected equipment.
  • Manual Reset: After tripping due to an overcurrent event, the circuit breaker can be manually reset, restoring the circuit to normal operation.

Advantages and Disadvantages

Advantages

  • Compact Design: The compact size of the W58-XB1A4A-2 allows for easy integration into various electrical systems.
  • Reliable Performance: This circuit breaker offers consistent and reliable overcurrent protection, ensuring the safety of the connected equipment.

Disadvantages

  • Limited Current Rating: With a current rating of 5A, the W58-XB1A4A-2 may not be suitable for high-current applications.

Working Principles

The W58-XB1A4A-2 operates based on the principle of thermal-magnetic protection. When an overcurrent condition occurs, the internal bimetallic strip heats up, causing it to bend and trip the circuit breaker. This mechanism provides both thermal and magnetic protection, making it effective in a wide range of applications.

Detailed Application Field Plans

The W58-XB1A4A-2 is commonly used in various electrical systems, including: - Automotive Electronics - Industrial Control Panels - Power Distribution Units - Telecommunications Equipment

Detailed and Complete Alternative Models

  • W58-XB1A4A-3: Similar specifications with a higher current rating of 10A
  • W58-XB1A4A-1: Similar specifications with a lower current rating of 3A
  • W58-XB1A4A-4: Similar specifications with additional built-in auxiliary contacts

In conclusion, the W58-XB1A4A-2 thermal circuit breaker offers reliable overcurrent protection in a compact and easy-to-install package. Its functional features, advantages, and application versatility make it a valuable component in various electrical systems.

[Word Count: 410]

10個與W58-XB1A4A-2在技術方案中應用相關的常見問題與解答

  1. What is the W58-XB1A4A-2?

    • The W58-XB1A4A-2 is a thermal circuit breaker commonly used in electrical and electronic applications to protect circuits from overcurrent or short circuit conditions.
  2. What is the voltage and current rating of the W58-XB1A4A-2?

    • The W58-XB1A4A-2 has a voltage rating of 250VAC and a current rating of 10A.
  3. How does the W58-XB1A4A-2 function?

    • The W58-XB1A4A-2 functions by automatically disconnecting the circuit when it detects an overcurrent or short circuit, thus protecting the connected equipment.
  4. What are the typical applications of the W58-XB1A4A-2?

    • The W58-XB1A4A-2 is commonly used in power supplies, industrial equipment, appliances, and automotive systems to provide overcurrent protection.
  5. Is the W58-XB1A4A-2 suitable for use in harsh environments?

    • Yes, the W58-XB1A4A-2 is designed to withstand harsh environmental conditions and is suitable for use in demanding applications.
  6. What are the mounting options for the W58-XB1A4A-2?

    • The W58-XB1A4A-2 can be mounted using various methods, including panel mount, through-hole mount, and bracket mount, providing flexibility in installation.
  7. Does the W58-XB1A4A-2 have any certifications or approvals?

    • Yes, the W58-XB1A4A-2 is typically UL recognized and meets various international standards for safety and performance.
  8. Can the W58-XB1A4A-2 be reset after tripping?

    • Yes, the W58-XB1A4A-2 can be manually reset after tripping, allowing for easy restoration of the circuit.
  9. What is the operating temperature range of the W58-XB1A4A-2?

    • The W58-XB1A4A-2 has an operating temperature range of -40°C to 85°C, making it suitable for a wide range of environments.
  10. Are there any special considerations for integrating the W58-XB1A4A-2 into a circuit design?

    • It's important to ensure proper derating and thermal management to maximize the performance and reliability of the W58-XB1A4A-2 in a given application.