圖片可能僅供參考。
有關產品詳細信息,請參閱規格。
P51-750-A-M-M12-20MA-000-000

P51-750-A-M-M12-20MA-000-000

Basic Information Overview

Category

The P51-750-A-M-M12-20MA-000-000 belongs to the category of pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial and commercial applications.

Characteristics

  • High accuracy
  • Wide operating temperature range
  • Compact size
  • Robust construction

Package

The sensor is typically packaged in a protective housing with appropriate connectors for easy installation.

Essence

The essence of the P51-750-A-M-M12-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in diverse environments.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-750 psi
  • Output Signal: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Supply Voltage: 12-30 VDC
  • Accuracy: ±0.5% full scale

Detailed Pin Configuration

The detailed pin configuration of the P51-750-A-M-M12-20MA-000-000 is as follows: 1. Power Supply (+) 2. Power Supply (-) 3. Signal Output 4. Ground

Functional Features

  • High precision pressure measurement
  • Compatibility with various media types
  • Long-term stability
  • Overpressure protection

Advantages

  • Accurate and reliable measurements
  • Suitable for harsh environments
  • Low power consumption
  • Easy integration into existing systems

Disadvantages

  • Higher initial cost compared to some alternatives
  • May require periodic calibration

Working Principles

The P51-750-A-M-M12-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an output signal that corresponds to the applied pressure.

Detailed Application Field Plans

The P51-750-A-M-M12-20MA-000-000 is widely used in: - Industrial automation - Hydraulic systems - Process control - HVAC systems - Aerospace and automotive industries

Detailed and Complete Alternative Models

Some alternative models to the P51-750-A-M-M12-20MA-000-000 include: - P52-500-B-N-N12-30MA-000-000 - P55-1000-C-M-M12-20MA-000-000 - P60-300-D-P-M12-20MA-000-000

In conclusion, the P51-750-A-M-M12-20MA-000-000 is a highly accurate and reliable pressure sensor suitable for a wide range of applications, despite its initial cost and periodic calibration requirements. Its robust construction and precise measurements make it an essential component in various industries.

[Word count: 443]

10個與P51-750-A-M-M12-20MA-000-000在技術方案中應用相關的常見問題與解答

  1. What is the P51-750-A-M-M12-20MA-000-000 used for?

    • The P51-750-A-M-M12-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in various technical solutions.
  2. What is the operating range of the P51-750-A-M-M12-20MA-000-000?

    • The operating range of the P51-750-A-M-M12-20MA-000-000 is typically from 0 to 750 psi, making it suitable for a wide range of pressure measurement applications.
  3. How does the P51-750-A-M-M12-20MA-000-000 communicate pressure readings?

    • The P51-750-A-M-M12-20MA-000-000 communicates pressure readings using a 4-20mA output signal, which can be easily integrated into control systems and data acquisition devices.
  4. Is the P51-750-A-M-M12-20MA-000-000 suitable for harsh environments?

    • Yes, the P51-750-A-M-M12-20MA-000-000 is designed to withstand harsh environments and is often used in industrial and outdoor applications.
  5. What are the typical industries that use the P51-750-A-M-M12-20MA-000-000?

    • The P51-750-A-M-M12-20MA-000-000 is commonly used in industries such as automotive, aerospace, manufacturing, and oil & gas for pressure monitoring and control.
  6. Can the P51-750-A-M-M12-20MA-000-000 be calibrated?

    • Yes, the P51-750-A-M-M12-20MA-000-000 can be calibrated to ensure accurate pressure measurements based on specific application requirements.
  7. What are the installation requirements for the P51-750-A-M-M12-20MA-000-000?

    • The P51-750-A-M-M12-20MA-000-000 typically requires a secure mounting position and proper sealing to prevent leaks and ensure accurate readings.
  8. Does the P51-750-A-M-M12-20MA-000-000 require regular maintenance?

    • Generally, the P51-750-A-M-M12-20MA-000-000 is designed for long-term reliability and may only require periodic inspection and calibration.
  9. Can the P51-750-A-M-M12-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, the 4-20mA output signal of the P51-750-A-M-M12-20MA-000-000 allows for seamless integration with PLCs and SCADA systems for real-time monitoring and control.
  10. Are there any special considerations when using the P51-750-A-M-M12-20MA-000-000 in hazardous areas?

    • When used in hazardous areas, the P51-750-A-M-M12-20MA-000-000 should comply with relevant safety standards and may require additional protective measures to ensure safe operation.