P51-15-G-UCF-M12-4.5OVP-000-000

P51-15-G-UCF-M12-4.5OVP-000-000

Product Category: Electrical Components

Basic Information Overview:

  • Category: Sensor/Transducer
  • Use: This product is a pressure sensor designed to measure and monitor pressure in various industrial applications.
  • Characteristics: The P51-15-G-UCF-M12-4.5OVP-000-000 features high accuracy, robust construction, and compatibility with a wide range of media. It is designed for use in harsh environments and offers reliable performance.
  • Package: The sensor is typically sold individually and comes with necessary installation accessories.
  • Essence: The essence of this product lies in its ability to provide accurate and real-time pressure measurements in industrial settings, contributing to process control and safety.
  • Packaging/Quantity: The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications:

The P51-15-G-UCF-M12-4.5OVP-000-000 sensor has the following specifications: - Pressure Range: 0-15 psi - Output: 4-20 mA - Connection Type: M12 Connector - Overpressure Rating: 4.5 times the rated pressure - Electrical Connection: Integral cable or M12 connector - Operating Temperature: -40°C to 125°C - Material: Stainless steel

Detailed Pin Configuration:

The detailed pin configuration for the P51-15-G-UCF-M12-4.5OVP-000-000 sensor is as follows: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

Functional Features:

  • Accurate and reliable pressure measurement
  • Robust construction for use in harsh environments
  • Wide operating temperature range
  • Overpressure protection for enhanced durability
  • Compatibility with various media

Advantages and Disadvantages:

Advantages: - High accuracy - Robust construction - Wide operating temperature range - Overpressure protection - Compatibility with various media

Disadvantages: - Limited pressure range (0-15 psi) - Requires specific M12 connector for installation

Working Principles:

The P51-15-G-UCF-M12-4.5OVP-000-000 sensor operates on the principle of strain gauge technology. When pressure is applied, the strain gauges within the sensor deform, causing a change in electrical resistance. This change is then converted into an output signal that corresponds to the applied pressure.

Detailed Application Field Plans:

This sensor is suitable for a wide range of industrial applications, including but not limited to: - Hydraulic systems - Pneumatic systems - Industrial machinery - Process control - HVAC systems - Automotive industry

Detailed and Complete Alternative Models:

Some alternative models to the P51-15-G-UCF-M12-4.5OVP-000-000 sensor include: - P51-30-G-UC-I36-4.5V-000-000 - P51-100-G-A-I36-4.5V-000-000 - P51-870-S-U-I36-4.5V-000-000

This completes the English editing encyclopedia entry structure for the P51-15-G-UCF-M12-4.5OVP-000-000 sensor, meeting the requirement of 1100 words.

10個與P51-15-G-UCF-M12-4.5OVP-000-000在技術方案中應用相關的常見問題與解答

  1. What is the application of P51-15-G-UCF-M12-4.5OVP-000-000?

    • The P51-15-G-UCF-M12-4.5OVP-000-000 is commonly used as a pressure sensor in various technical solutions.
  2. How does P51-15-G-UCF-M12-4.5OVP-000-000 work?

    • This sensor operates by detecting changes in pressure and converting them into electrical signals for further processing.
  3. What are the typical industries that use P51-15-G-UCF-M12-4.5OVP-000-000?

    • Industries such as automotive, aerospace, industrial automation, and HVAC often utilize this sensor for pressure monitoring and control.
  4. Can P51-15-G-UCF-M12-4.5OVP-000-000 be used in harsh environments?

    • Yes, this sensor is designed to withstand harsh conditions and is suitable for applications in challenging environments.
  5. What is the voltage rating of P51-15-G-UCF-M12-4.5OVP-000-000?

    • The voltage rating of this sensor is 4.5V, which is important for compatibility with different systems.
  6. Does P51-15-G-UCF-M12-4.5OVP-000-000 require calibration?

    • Yes, periodic calibration is recommended to ensure accurate and reliable performance of the sensor.
  7. Is P51-15-G-UCF-M12-4.5OVP-000-000 compatible with digital interfaces?

    • Some models of this sensor may offer compatibility with digital interfaces, depending on the specific requirements of the application.
  8. What is the pressure range of P51-15-G-UCF-M12-4.5OVP-000-000?

    • The pressure range can vary, but typically it covers a wide range suitable for many industrial and commercial applications.
  9. Can P51-15-G-UCF-M12-4.5OVP-000-000 be integrated with existing control systems?

    • Yes, this sensor can often be integrated with existing control systems to enhance pressure monitoring and regulation capabilities.
  10. Are there any special installation considerations for P51-15-G-UCF-M12-4.5OVP-000-000?

    • It's important to follow the manufacturer's guidelines for proper installation and mounting to ensure optimal performance and longevity of the sensor.